evaporative air cooler – Thong gio lam mat http://hungnghiep.vn Chuyen cung cap he thong thong gio lam mat Sun, 28 Jan 2024 08:56:42 +0000 en-GB hourly 1 https://wordpress.org/?v=4.8.23 EVAPORATIVE COOLING PAD 5090 http://hungnghiep.vn/sp/evaporative-cooling-pad-5090-2/ Sun, 10 Jan 2016 07:14:09 +0000 http://hungnghiep.vn/?post_type=product&p=655 ]]> Evaporative Cooling Pad 5090, is made of special cellulose paper and highly endosmotic water, with physical flutes having height of wave 5mm.

]]>
EVAPORATIVE AIR COOLER KT-18DS http://hungnghiep.vn/sp/evaporative-air-cooler-kt-18ds/ Sun, 10 Jan 2016 07:05:57 +0000 http://hungnghiep.vn/?post_type=product&p=645 Technical parameters of Air Cooler KT-18DS
Model Evaporative Air Cooler KT-18DS
Cover of the cooler PP plastic protecting it from harsh condition of weather and ultraviolet rays
Blades of axial fan Three blades like kestrel’s wing
Cooling capacity m3/h 18.000
Air pressure Pa 150
Type of flow Axial flow, bottom outlet
Motor capacity KW 1,1
Electric current A 2,8
Power V/Hz 3 phase 380V, 50Hz / 1 phase 220V, 50Hz
Mode of water supply Centralized/independent
Tank capacity Litres 25
Water consumption L/h 40
Noise dB 68
Size LxWxH mm 1090x1090x980
Size of outlet mm 670 x 670
Weight Kg 65
Effective Area m2 100 ÷ 150
Wind Distance m 15
  The typical methods of installation
 18DS_6  18DS_7
]]>
Composition of Air Cooler KT-18DS

The cooler has bottom outlet and it includes the following main parts:

–          Cover of the cooler: it is made of PP plastic protecting it from harsh condition of weather and ultraviolet rays;

–          One axial fan including three or nine blades like kestrel’s wing and large airflow;

–          Four frames of evaporative cooling pads (model 5090) at four sides and attaching cleansing wind net;

–          Four sets for dividing and distributing water for four frames of evaporative cooling pads;

–          One water pump: supplying water for frames of evaporative cooling pads;

–          One automatic valve for supplying water and one automatic valve for letting out;

–          One set of power and electronic control;

–          The bottom of the cooler: containing water and put together equipments including axial fan, water pump, float, control equipment,..

Operation principle of Air Cooler KT-18DS

The cooler operates under the principle of evaporation. The process treating temperature-humidity between water and air is happened in the space of machine room by axial fan with large air flow, cooling pad and water pump. Fresh and cool air in the machine room wil be pumped into workshop by axial fan through the system of wind pipeline. Dry and hot air and dust inside workshop is pushed out by differential pressure.The cooler has small and tidy composition with the system of air pipelines leading fresh and cool air into the area needing to be made cool. For this reason, we can apply to make cool air for total workshop or a part of workshop.  18DS_5
]]>
EVAPORATIVE AIR COOLER KT-18BS http://hungnghiep.vn/sp/evaporative-air-cooler-kt-18bs-2/ Sun, 10 Jan 2016 07:02:40 +0000 http://hungnghiep.vn/?post_type=product&p=641 Technical parameters of Air Cooler KT-18BS
Model Evaporative Air Cooler KT-18BS
Cover of the cooler PP plastic protecting it from harsh condition of weather and ultraviolet rays
Blades of axial fan Three blades like kestrel’s wing
Cooling capacity m3/h 18.000
Air pressure Pa 150
Type of flow Axial flow, side outlet
Motor capacity KW 1,1
Electric current A 2,8
Power V/Hz 3 phase 380V, 50Hz / 1 phase 220V, 50Hz
Mode of water supply Centralized/independent
Tank capacity Litres 25
Water consumption L/h 40
Noise dB 70
Size LxWxH mm 1090x1090x980
Size of outlet mm 670 x 670
Weight Kg 66
Effective Area m2 100 ÷ 150
Wind Distance m 15
]]>
Composition of Air Cooler KT-18BS

The cooler has side outlet and it includes the following main parts:

–          Cover of the cooler: it is made of PP plastic protecting it from harsh condition of weather and ultraviolet rays;

–          One axial fan including three or nine blades like kestrel’s wing and large airflow;

–          Three frames of evaporative cooling pads (model 5090) at three sides and attaching cleansing wind net;

–          Three sets for dividing and distributing water for three frames of evaporative cooling pads;

–          One water pump: supplying water for frames of evaporative cooling pads;

–          One automatic valve for supplying water and one automatic valve for letting out;

–          One set of power and electronic control;

–          The bottom of the cooler: containing water and put together equipments.

]]>
EVAPORATIVE AIR COOLER KT-18AS http://hungnghiep.vn/sp/evaporative-air-cooler-kt-18as-2/ Sun, 10 Jan 2016 07:01:46 +0000 http://hungnghiep.vn/?post_type=product&p=638 Technical parameters of Air Cooler KT-18AS
Model Evaporative Air Cooler KT-18AS
Cover of the cooler PP plastic protecting it from harsh condition of weather and ultraviolet rays
Blades of axial fan Three blades like kestrel’s wing
Cooling capacity m3/h 18.000
Air pressure Pa 150
Type of flow Axial flow, top outlet
Motor capacity KW 1,1
Electric current A 2,8
Power V/Hz 3 phase 380V, 50Hz / 1 phase 220V, 50Hz
Mode of water supply Centralized/independent
Tank capacity Litres 25
Water consumption L/h 40
Noise dB 72
Size LxWxH mm 1090x1090x980
Size of outlet mm 670 x 670
Weight Kg 68
Effective Area m2 100 ÷ 150
Wind Distance m 15
]]>
Composition of Air Cooler KT-18AS

The cooler has top outlet and it includes the following main parts:

–          Cover of the cooler: it is made of PP plastic protecting it from harsh condition of weather and ultraviolet rays;

–          One axial fan including three or nine blades like kestrel’s wing and large airflow;

–          Four frames of evaporative cooling pads (model 5090) at four sides and attaching cleansing wind net;

–          Four sets for dividing and distributing water for four frames of evaporative cooling pads;

–          One water pump: supplying water for frames of evaporative cooling pads;

–          One automatic valve for supplying water and one automatic valve for letting out;

–          One set of power and electronic control;

–          The bottom of the cooler: containing water and put together equipments.

]]>
EVAPORATIVE AIR COOLER 20000m3/h http://hungnghiep.vn/sp/evaporative-air-cooler-20000m3h/ Sun, 10 Jan 2016 06:57:56 +0000 http://hungnghiep.vn/?post_type=product&p=632 Model: KT-20DS
  • Axial flow, bottom outlet
  • Cooling capacity: 20.000 m3/h
  • Motor capacity: 1,1KW
  • Power: 380V-50Hz
  • Size LxWxH: 1090x1090x980 mm
  • Size of outlet: 670×670 mm
]]>
Model: KT-20DS

  • Axial flow, bottom outlet
  • Cooling capacity: 20.000 m3/h
  • Motor capacity: 1,1KW
  • Power: 380V-50Hz
  • Size LxWxH: 1090x1090x980 mm
  • Size of outlet: 670×670 mm
]]>
EVAPORATIVE AIR COOLER 23000m3/h http://hungnghiep.vn/sp/evaporative-air-cooler-23000m3h/ Sun, 10 Jan 2016 06:54:59 +0000 http://hungnghiep.vn/?post_type=product&p=631 Model: KT-23DS
  • Axial flow, bottom outlet
  • Cooling capacity: 23.000 m3/h
  • Motor capacity: 1,5KW
  • Power: 380V-50Hz
  • Size LxWxH: 1090x1090x980 mm
  • Size of outlet: 670×670 mm
]]>
Model: KT-23DS

  • Axial flow, bottom outlet
  • Cooling capacity: 23.000 m3/h
  • Motor capacity: 1,5KW
  • Power: 380V-50Hz
  • Size LxWxH: 1090x1090x980 mm
  • Size of outlet: 670×670 mm
]]>
EVAPORATIVE AIR COOLER 30000m3/h http://hungnghiep.vn/sp/evaporative-air-cooler-30000m3h/ Sun, 10 Jan 2016 06:46:53 +0000 http://hungnghiep.vn/?post_type=product&p=630 Model: KT-30DS
  • Axial flow, bottom outlet
  • Cooling capacity: 30.000 m3/h
  • Motor capacity: 3KW
  • Power: 380V-50Hz
  • Size LxWxH: 1260x1260x1160 mm
  • Size of outlet: 795×795 mm
]]>
Model: KT-30DS

  • Axial flow, bottom outlet
  • Cooling capacity: 30.000 m3/h
  • Motor capacity: 3KW
  • Power: 380V-50Hz
  • Size LxWxH: 1260x1260x1160 mm
  • Size of outlet: 795×795 mm
]]>
Keruilai evaporative air cooler http://hungnghiep.vn/sp/keruilai-evaporative-air-cooler-2/ Sun, 10 Jan 2016 06:41:19 +0000 http://hungnghiep.vn/?post_type=product&p=628
The typical methods of installation:
 KF60_5  KF60_6  KF60_7
Floor standing installation Wall mounting installation Mobility with high mental base
 KF60_8  KF60_9
Mobility with low mental base Hanging installation
]]>
APPLICATIONS:

  • In the industry such as workshops producing garments, woolen yard, shoes, packing, mechanics, pottery and china, knitting rattan and bamboo, garage,…
  • In the services such as restaurant, supermarket, public bar, amusement park,…
  • In the farm such as arboretums, places growing flowers, pot plant,…
  • In the livestock such as places breeding cattle and poultry,….

The typical methods of installation:

 KF60_5  KF60_6  KF60_7
Floor standing installation Wall mounting installation Mobility with high mental base
 KF60_8  KF60_9
Mobility with low mental base Hanging installation
]]>
Cooling system making positive pressure http://hungnghiep.vn/sp/cooling-system-making-positive-pressure-2/ Sun, 27 Dec 2015 22:11:54 +0000 http://hungnghiep.vn/?post_type=product&p=625

The system of evaporative air coolers making positive pressure is a system blowing fresh and cool air into a workshop and combining the following equipments:

  1. Evaporative air coolers having large capacity and airflow;
  2. Pipelines lead fresh and cool air into a workshop;
  3. Diffuse shutters: Distributing fresh and cool air into a workshop;
  4. Supports and machine platforms;
  5. Circulative tanks;
  6. Water pumps: Supplying water for  evaporative air coolers;
  7. Electric box: Controlling equipments of the system;
  8. Electric equipments and material.
]]>
The system of evaporative air coolers making positive pressure is a system blowing fresh and cool air into a workshop and combining the following equipments:

  1. Evaporative air coolers having large capacity and airflow;
  2. Pipelines lead fresh and cool air into a workshop;
  3. Diffuse shutters: Distributing fresh and cool air into a workshop;
  4. Supports and machine platforms;
  5. Circulative tanks;
  6. Water pumps: Supplying water for  evaporative air coolers;
  7. Electric box: Controlling equipments of the system;
  8. Electric equipments and material.

Evaporative air coolers are installed steady arrangement on all space of a workshop ( making fresh and cool air for all space of the workshop) or only installed to concentrate on parts of the workshop where employees do their works (making fresh and cool air for parts of the workshop). As a result, this system saves investment expenses and electric consumption, but it still makes clear and cool working environment.

When the system of evaporative air coolers operate, water will evaporate into air to decrease air temperature partially, the rest of water return to continue a new circulation, simultaneously, volume of water is also supplied additionally to compensate for partial water evaporating. That is the circulation of water in this system, it helps us to save water and other expenses. Moreover, because volume of water is changed regularly, it helps the system to operate more effective and air flow blowing into the workshop to become cleaner and cooler.

The most salient feature of the system of evaporative air coolers making positive pressure:

  • Low expenses of investment and operation: Its investment expenses and electric consumption is correlatively equal 30% and 10% to the system of air conditioners.
  • High effect: Air through the coolers will be cleansed and made cool to become abundant oxygen. As a result, the coolers will make ideal environment to increase productivity and guarantee health for employees.
]]>